Capnography & Gas Monitoring
Nomoline™ Adapter
No moisture sampling for extended monitoring of non-intubated patients
Advanced technology enables cost-effective, hassle-free sidestream capnography and gas measurements
- > Reduces disposable costs through:
- • Extended monitoring time in low- and high-humidity environments
- • Uses non-proprietary cannulas
- > Patented polymer allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gas measurements unaffected and eliminating the need for a water trap and associated clogging
- > Hydrophobic bacterial filter designed to prevent cross-contamination and to protect module from bacteria and water intrusion
- > Designed for low sampling flow applications and to be functional in any patient position, to support use in a wide range of clinical applications and patient populationsn
How Nomoline Works
Nomoline allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gas measurements unaffected.
- Gas sample enters Nomoline adapter from patient breathing circuit and passes through the gas sample tube
- Nomo polymer absorbs water from the patient’s gas sample and evaporates it into surrounding air
- Gas sample is transported through the remaining sample tube and passes through the water/bacteria filter
- Gas sample enters the sidestream module where it is analyzed to accurately determine gas concentration
How Nomoline Works
The ISA™ module with Nomoline sampling lines connect to the Root® patient monitoring platform via Masimo Open Connect™ (MOC-9™) ports.
Root capabilities expand with ISA to include real-time capnography and gas measurements
PDF Resources
SIGMA: English |
Anesthesia Gas Monitoring: Evolution of a de facto Standard of Care |
Nomoline: Trouble-free sidestream gas analysis |
Sell Sheet: Nomoline™ Airway Adapter Set |
Sell Sheet: Nomoline Adapter |
Caution: Federal law restricts this device to sale by or on the order of a physician.
Providing the ultimate sidestream performance along with cost-effective disposables
Click here to receive more information about ISA Capnography
The ISA™ CO2 module for the Root® patient monitoring and connectivity platform provides flexible applications across the continuum of care
- > Displays end-tidal carbon dioxide (EtCO2) waveform and measurements and trends of EtCO2, fractional concentration of inspired carbon dioxide (FiCO2), and respiration rate (RR)
- > Appropriate for monitoring infant, pediatric, or adult patients in a range of hospital environments including the OR, ICU, and medical-surgical units
- > Saves time in critical situations with virtually no warm-up time and full accuracy performance in ten seconds
- > Supports quiet environment initiatives with no disturbing pump noises
- > Generally requires 50 ml/minute sampling flow to support patient monitoring
- > External module enables easy movement for use on multiple Root monitors
Nomoline™–No moisture sampling lines and non-proprietary cannulas
- > Reduces disposable costs through:
- • Extended monitoring time in low- and high-humidity environments
- • Use of non-proprietary cannulas
- > Revolutionary design eliminates the need for a water trap
- > Patented polymer allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gases unaffected
- > Hydrophobic bacterial filter protects ISA analysers from water intrusion and cross-contamination
|
|
|
Nomoline Airway Adapter Set for Intubated Patients | Nomoline Adapter for use with non-proprietary Cannulas |
- > The portable ISA CO2 module easily mounts to the back of the Root patient monitoring platform and connects via Masimo Open Connect™ (MOC-9™) ports on the side
*The following accuracy specifications are valid for dry single gases at 22 ± 5 °C and 1013 ± 40 kPa.
PDF Resources
Data Sheet: ISA Capnograph |
Sell Sheet: Nomoline Adapter |
||
Sell Sheet: Nomoline™ Airway Adapter Set |
Caution: Federal law restricts this device to sale by or on the order of a physician.
Immediate capnometry at your fingertips
- > Small, portable capnometer, EMMA requires virtually no warm-up time, with full accuracy in
15 seconds to measure end-tidal carbon dioxide (EtCO2) and respiration rate - > Compact, lightweight design fits in the palm of your hand for unmatched mobility and convenience
- > Used for short-term EtCO2 monitoring for adult, pediatric, and infant patients
- > Flexible use at multiple points of care, including pre-hospital, emergency medicine, operating room, intensive care unit, and long-term acute care
- > Helps clinicians assess the effectiveness of CPR and guide ventilation, allowing them to make adjustments in the course of treatment, breath by breath
- > Rugged, water-resistant design for reliable operation in challenging environments
- > Easy to maintain — no routine calibration required
Features
- > Simple, easy-to-use interface for quick setup and one-touch programming
- > Audible and visual alarm system for No Breath Detected, No Adapter, Check Adapter, and adjustable high and low EtCO2 alarm
- > Long battery life—up to 12 hours of normal use with two standard AAA lithium batteries
Kit
- EMMA Kit*
- EMMA (mmHg) PN 9632
- EMMA (kPa) PN 9633
Accessories
EMMA Airway Adapter
- Adult/Pediatric
- Box of 25
- PN 17448
EMMA Airway Adapter
- Infant
- Box of 10
- PN 17449
* In order for the EMMA Kit to provide readings, either of the listed airway adapters is required. Kit includes EMMA, pouch, and lanyard.
PDF Resources
Data Sheet: EMMA Mainstream Capnometer |
Whitepaper: Emerging Use of Capnometry in Emergency Medicine |
Immediate capnography at your fingertips
- > Immediate results — EMMA requires virtually no warm-up time, with full accuracy in 15 seconds to measure end-tidal carbon dioxide (EtCO2) and respiration rate (RR)
- > Continuous capnogram allows for confirmation of endotracheal tube placement, enables clinicians to assess the depth and effectiveness of compressions, and allows clinicians to recognize return of spontaneous circulation (ROSC)
- > Small, portable capnograph — lightweight design fits in the palm of your hand for unmatched mobility and convenience during short-term EtCO2 monitoring of adult, pediatric, and infant patients
- > Flexible use at multiple points of care, including pre-hospital, emergency medicine, operating room, intensive care unit, and long-term acute care
- > Helps clinicians assess the effectiveness of CPR and guide ventilation, allowing them to make adjustments in the course of treatment, breath by breath
- > Rugged, water-resistant design for reliable operation in challenging environments
- > Easy to maintain — no routine calibration required
Features
- > Clear, continuous capnogram of carbon dioxide values
- > Simple, easy-to-use interface for quick set-up and one-touch programming
- > Audible and visual alarm system for No Adapter, Clogged Adapter, No Breath (Apnea), Low Battery and adjustable High and Low EtCO2 alarm
- > Long battery life—up to 10 hours of normal use with two standard AAA lithium batteries
Kit
- EMMA Kit*
- EMMA (mmHg) PN 3639
- EMMA (kPa) PN 3678
Accessories
- EMMA Airway Adapter
- Adult/Pediatric
- Box of 25
- PN 17448
- EMMA Airway Adapter
- Infant
- Box of 10
- PN 17449
* In order for the EMMA Kit to provide readings, either of the listed airway adapters is required. Kit includes EMMA, pouch, and lanyard.
PDF Resources
Data Sheet: EMMA Capnograph |
Whitepaper: Emerging Use of Capnometry in Emergency Medicine |
Nomoline™ Adapter
No moisture sampling for extended monitoring of non-intubated patients
Advanced technology enables cost-effective, hassle-free sidestream capnography and gas measurements
- > Reduces disposable costs through:
- • Extended monitoring time in low- and high-humidity environments
- • Uses non-proprietary cannulas
- > Patented polymer allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gas measurements unaffected and eliminating the need for a water trap and associated clogging
- > Hydrophobic bacterial filter designed to prevent cross-contamination and to protect module from bacteria and water intrusion
- > Designed for low sampling flow applications and to be functional in any patient position, to support use in a wide range of clinical applications and patient populationsn
How Nomoline Works
Nomoline allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gas measurements unaffected.
- Gas sample enters Nomoline adapter from patient breathing circuit and passes through the gas sample tube
- Nomo polymer absorbs water from the patient’s gas sample and evaporates it into surrounding air
- Gas sample is transported through the remaining sample tube and passes through the water/bacteria filter
- Gas sample enters the sidestream module where it is analyzed to accurately determine gas concentration
How Nomoline Works
The ISA™ module with Nomoline sampling lines connect to the Root® patient monitoring platform via Masimo Open Connect™ (MOC-9™) ports.
Nomoline adapter with cannula is plugged into the ISA module
ISA module easily mounts to the back of the Root and connects via the MOC-9 ports on the side
Root capabilities expand with ISA to include real-time capnography and gas measurements
PDF Resources
SIGMA: English |
Anesthesia Gas Monitoring: Evolution of a de facto Standard of Care |
Nomoline: Trouble-free sidestream gas analysis |
Sell Sheet: Nomoline™ Airway Adapter Set |
Sell Sheet: Nomoline Adapter |
Caution: Federal law restricts this device to sale by or on the order of a physician.